<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-07 07-28-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 61 dBuV P3 SR
Pilot RDS Phase Difference
5.6 kHz 2.5 kHz 6 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 20 kHz 15425 0,1232
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-4,6 dBr -3,17 dBr -1,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 12 (Easy M) 0 1 1 9 6:28, 7.01.2026
RT
"Timbuktu - The Botten Is Nådd "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E201, E402, E424
FM Scope Max at: 20 kHz MIN: 12 kHz % above 76 kHz: 0,1232 Acquired: 2026/01/07 7.27.18 Total samples: 15425 Equivalent time: 0:12:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -1,0 dBr MIN: -4,6 dBr AVE: -3,17 dBr % above 12,2 dBr: 0,0 Last value: -3,6 dBr (2026/01/07 7.27.18) 07.14 07.16 07.18 07.20 07.22 07.24 07.26 -4 -2 0 Pm [dBr]